Home › Technical resources › AWS vs ISO
AWS A5.12 vs ISO 6848: Tungsten Electrode Designations
The same tungsten electrode is often described three ways: an AWS classification such as EWLa-2, a works or ISO-style designation such as WL20, and a tip colour such as blue. Purchase orders mix these freely, which is a common source of receiving the wrong type. This page explains how the naming systems relate and which one to put on an order.
Two naming systems, one set of electrodes
AWS A5.12 / A5.12M is the American Welding Society specification for tungsten and tungsten-alloy electrodes. Its classifications begin with EW (electrode, tungsten) followed by the alloying element and, in most cases, a nominal oxide level: EWP (pure), EWTh-1 / EWTh-2 (thoria), EWCe-2 (ceria), EWLa-1 / EWLa-1.5 / EWLa-2 (lanthana), EWZr-1 / EWZr-8 (zirconia) and EWG (a rare-earth mixture without a specified single oxide).
ISO 6848 is the international counterpart and is the basis for the short designations most catalogues use: WP, WT10 / WT20, WC20, WL10 / WL15 / WL20, WZ3 / WZ8. Chinese and European supplier catalogues often use these short codes, sometimes written WT20, WL15 or WZ8 without the W prefix. The two systems are not word-for-word identical in scope or test method, but in commercial practice the families below are treated as counterparts.
Commonly used counterparts and tip colours
| Family | AWS classification | Common ISO / trade designation | Typical tip colour |
|---|---|---|---|
| Pure tungsten | EWP | WP | Green |
| 1% thoria | EWTh-1 | WT10 | Yellow |
| 2% thoria | EWTh-2 | WT20 | Red |
| 2% ceria | EWCe-2 | WC20 | Grey |
| 1% lanthana | EWLa-1 | WL10 | Black |
| 1.5% lanthana | EWLa-1.5 | WL15 | Gold |
| 2% lanthana | EWLa-2 | WL20 | Blue |
| Zirconia, low | EWZr-1 | WZ3 | Brown |
| Zirconia, higher | EWZr-8 | WZ8 | White |
| Rare-earth mix | EWG | Composite / mixed | Purple (varies) |
Colour codes are a convention, not a guarantee. The table reflects the widely used AWS / ISO colour pattern, but markings vary by manufacturer, by market and by product generation — and WY20 (yttriated) and composite types have no single universally agreed colour. Confirm the marking on the quotation and on the box, and see our colour code chart for the types we supply. Oxide percentages above are nominal catalogue descriptions, not certified analysis values; the certificate of analysis is the controlling document.
Which designation should go on the purchase order?
Use one unambiguous classification and let the rest be confirmation, not a second specification. A workable order line looks like this:
Write the AWS or ISO designation, then the diameter and length from the size table, the quantity, the tip colour you expect, and the packing. Adding both naming systems is fine as long as they agree — if they disagree, ask before the order is produced. For choosing between families by current type and workpiece, use the selection guide rather than the designation table.
Thoriated electrodes and handling
EWTh-1 / EWTh-2 contain thorium oxide and remain popular for DC steel work because they start easily and carry high current. Thoria is a low-level radioactive material: grinding dust and disposal are regulated in many markets, and many buyers have moved to ceriated or lanthanated types for that reason. If your site rules restrict thoriated consumables, say so at enquiry stage and we will quote a non-thoriated alternative with a comparable duty range. Follow your local safety rules for grinding dust extraction and waste handling regardless of type.
What we confirm before production
- Classification or trade designation, and the exact tip colour / marking you expect on the box.
- Diameter and length, with diameter tolerance (h7 is our standard ground finish).
- Quantity per size, and whether mixed types and sizes may be combined in one order (they can).
- Packing: neutral, OEM brand box, label text and any barcode requirement — see packaging & OEM.
- Documents: certificate of analysis, packing list, commercial invoice and export documents for the agreed terms.
For the full product range, see all electrode types; for inspection scope and certificates, see quality control.
Ready to specify your order?
Send the type, diameter, length, quantity and packing. Mixed sizes are welcome from 100 pcs total per order.
Frequently asked questions
Are AWS and ISO designations interchangeable?
Commercially the commonly listed families are treated as counterparts, but the standards differ in classification scope and test method. Quote one system explicitly and use the other only as supporting information.
Can I rely on tip colour alone?
No. Colour is a helpful shop-floor identifier, not a specification. Markings differ between manufacturers and regions; confirm the designation on the order and the certificate.
Which non-thoriated type replaces WT20?
Buyers commonly move to WC20 (ceriated) for low-current DC work or WL15 / WL20 (lanthanated) for general DC and AC duty. The right choice depends on your current range and machine — see the selection guide.
Do you supply to both standards?
We supply by the designation written into the quotation, manufactured and marked accordingly. State the standard or trade code, tip marking and required documents at enquiry stage so they are confirmed before production.